The Predictive Value of Proportional Evaluation Based on the Metabolic Activity of Cervical Lymph Nodes on PET/CT Imaging in Patients with Larynx Cancer
PDF
Cite
Share
Request
Original Article
P: 59-64
June 2020

The Predictive Value of Proportional Evaluation Based on the Metabolic Activity of Cervical Lymph Nodes on PET/CT Imaging in Patients with Larynx Cancer

Mol Imaging Radionucl Ther 2020;29(2):59-64
1. University of Health Sciences Turkey, İstanbul Okmeydanı Training and Research Hospital, Clinic of Nuclear Medicine, İstanbul, Turkey
2. University of Health Sciences Turkey, İstanbul Okmeydanı Training and Research Hospital, Clinic of Otorhinolaryngology, İstanbul, Turkey
No information available.
No information available
Received Date: 05.09.2019
Accepted Date: 06.09.2019
Publish Date: 29.04.2020
PDF
Cite
Share
Request

ABSTRACT

Objectives:

We aimed to evaluate the proportional values of maximum standardized uptake value (SUVmax) for cervical lymph nodes on 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for prediction of the presence of metastasis in patients with larynx squamous cell cancer (LSCC).

Methods:

This retrospective study involved 43 patients with LSCC. All patients underwent resection of the primary tumor and neck dissection within 4 weeks after undergoing 18F-FDG PET/CT examinations. Receiver operating characteristic (ROC) analysis was performed to evaluate the lymph node SUVmax/primary tumor SUVmax (SUVmaxLN/SUVmaxPT), lymph node SUVmax/aortic SUVmax (SUVmaxLN/SUVmaxA), and lymph node SUVmax/liver SUVmax (SUVmaxLN/ SUVmaxL) ratios for diagnosis of lymph node metastasis.

Results:

SUVmaxLN/SUVmaxA, SUVmaxLN/SUVmaxL, and SUVmaxLN/SUVmaxPT rates were significantly higher in metastatic lymph nodes compared to non-metastatic nodes. ROC analysis for metastasis showed that the cut-off thresholds were 3.87 for SUVmaxLN; 1.78 for SUVmaxLN /SUVmaxA; 1.08 for SUVmaxLN/SUVmaxL; and 0.36 for SUVmaxLN/SUVmaxPT. The diagnostic sensitivity, specificity and AUC were 83.7%, 77%, 0.856 for SUVmaxLN; 79.7%, 84%, 1.78 for SUVmaxLN/SUVmaxA; 84.1%, 76%, 0.833 for SUVmaxLN/SUVmaxL; and 53.6%, 76%, 0.666 for SUVmaxLN/SUVmaxPT, respectively.

Conclusion:

SUVmaxLN/SUVmaxA, SUVmaxLN/SUVmaxL, and SUVmaxLN/SUVmaxPT ratios can be safely used for diagnosis of cervical lymph node metastasis in patients with LSCC.

Introduction

18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is being increasingly carried out to determine the stage and localization of metastatic disease in patients with larynx squamous cell cancer (LSCC). The correct diagnosis of metastatic cervical lymph nodes is important in terms of determining prognosis and providing adequate treatment. In clinical practice, CT and/or magnetic resonance imaging (MRI) are generally recommended for the assessment of tumor extension and cervical lymph node involvement (1).

Several studies in the literature reported that 18F-FDG PET/CT had reliable diagnostic value for a depiction of lymph node metastasis of head and neck squamous cell (HNSCC) compared with conventional CT/MRI (2,3). Meta-analyses of 18F-FDG PET/CT showed that the pooled per-patient, per-neck-side, and per-neck-level sensitivities/specificities were 0.91/0.87, 0.84/0.83, and 0.80/0.96, respectively. Across 13 studies (3460 neck levels) for which per-neck-level data were available, sensitivity and specificity were 0.84/0.96 respectively for 18F-FDG PET/CT and 0.63/0.96 for conventional imaging (CT and MRI), respectively (4).

Cut-off value of 2.5 for the maximum standardized  uptake value (SUVmax) is used commonly to differentiate between benign and malignant lesions on 18F-FDG PET/CT imaging. But many biological and technical factors can affect SUVmax value, such as patient’s weight, blood glucose level, postinjection uptake time, respiratory motion, tumor behavior, lesion size, motion artefacts, variability of the scanner, image-reconstruction parameters and contrast agent used (5,6). These factors may affect SUV values by 5% to 50% and cause false negativity or positivity (7).

In the literature, there are many studies on proportional values such as SUVmaxLN/ SUVmaxPT, SUVmaxLN/SUVmaxA, and SUVmaxLN/SUVmaxL for the prediction of metastatic lymph nodes in various malignancies, mainly lung cancer and breast cancer. However, the number of studies about LSCC is limited (8,9,10,11,12). In this study, we aimed to evaluate the proportional values of the SUVmax for cervical lymph nodes on 18F-FDG PET/CT imaging for the prediction of the presence of metastasis in patients with LSCC.

Materials and Methods

This retrospective study involved 43 patients (42 men,1 woman; mean age=60.20±8.12 years, range=46-83) with LSCC.

The following criteria were defined for patient selection:

- Patients with diagnosis ofprimary LSCC made by a biopsy.

- Patients who did not undergo any treatment for LSCC before 18F-FDG PET/CT imaging and had no secondary malignancy.

- Patients who did not undergo any diagnostic excisional or incisional cervical lymph node biopsy for metastasis evaluation before 18F-FDG PET/CT imaging.

- Patients who underwent resection of the primary tumor and neck dissection within 4 weeks after undergoing 18F-FDG PET/CT imaging.

18F-FDG PET/CT imaging was performed at our institution between November 2013 and January 2018. Ethics Committee Approval was obtained from Okmeydanı Training and Research Hospital Ethics Committee with the decision number “1066” and date “12.04.2018”. The written informed consent was obtained from all patients at the time of imaging.

18F-FDG PET/CT studies were carried out using an integrated PET/CT scanner, which consisted of a full-ring HI-REZ LSO PET and a 6-slice CT (Siemens Biograph 6; Siemens, Chicago, USA). All patients were instructed to fast for at least 6 h before the 18F-FDG injection. Blood glucose levels were measured before the study and the injection was given only when the blood glucose levels were below 11.11 mmol/L. The patients were injected with 370 to 555 MBq 18F-FDG, according to body weight. After 60 minutes of waiting on a semireclined relaxed chair, the patients were imaged using an integrated PET/CT scanner. The CT portion of the study was performed without injection of intravenous contrast medium to define anatomical landmarks and attenuate correction on PET images. CT was acquired first with the following parameters: 50 mAs, 140 kV, and 5 mm section thickness. Whole-body CT was performed in a craniocaudal direction. PET images were acquired in a three-dimensional mode, from the vertex to mid-thigh, with six to eight bed positions of 3 min each, and PET data were collected in a caudocranial direction. Image reconstruction used “ordered subsets expectation maximization” algorithm of 2 iterations and 8 subsets. Image analysis was carried out on the Esoft multimodality computer platform (Siemens Medical Solutions, Erlangen, Germany). 18F-FDG PET/CT images were retrospectively interpreted by 3 experienced nuclear medicine physicians. The observers were blinded to the results of preoperative diagnostic imaging examinations such as MRI or ultrasonography and to the histopathological evidence of lymph node dissections. All cervical lymph nodes on CT which increased tracer uptake compared with background activity were accepted as metastatic. Semi-quantitative analysis of 18FDG uptake was performed, through creation of a region of interest (ROI) over the primary lesion and lymph nodes. SUVmax was also determined by manually placing a cylindrical ROI over the arcus aorta and right lobe of the liver. Lymph node SUVmax values were divided by the SUVmax of the primary tumour, arcus aorta (mediastinal blood pool) and liver to calculate the following:

- Lymph node SUVmax/primary tumour SUVmax (SUVmaxLN/SUVmaxPT)

- Lymph node SUVmax/aortic SUVmax (SUVmaxLN/SUVmaxA)

- Lymph node SUVmax/Liver SUVmax (SUVmaxLN/SUVmaxL)

Operations were performed in our head and neck surgical clinic based on clinical and imaging findings. Modified radical neck dissection was performed in all patients. Lymph nodes and tumors were dissected from the specimens and stained with hematoxylin and eosin for histologic analysis. Serial histologic sections were used. We compared results of preoperative examinations using 18F-FDG PET/CT with those of the corresponding histopathologic examinations. If one lymph node showed increased uptake on 18F-FDG PET/CT images and had some findings on CT such as ≥10 mm diameter or round shape or hypoechogenicity or irregular margin or loss of fatty hilum findings and if histopathology showed lymph node with metastasis in the same neck level, this lymph node was accepted as a true positive finding for 18F-FDG PET/CT. If metastatic lymph node number on histopathology was lower than lymph node numbers that were accepted as metastatic on 18F-FDG PET/CT, the lymph node showing the lowest uptake was accepted as false positive. If metastatic lymph node number on histopathology was higher than lymph node number accepted as metastatic on 18F-FDG PET/CT, it was recorded as false-negative lymph node for 18F-FDG PET/CT.

Statistical Analysis

While evaluating the findings of the study, IBM SPSS Statistics 22 program (IBM SPSS, Turkey) was used for statistical analysis. The normal distribution of the parameters was evaluated by the Shapiro-Wilk test and it was found that the parameters did not show normal distribution. The Mann-Whitney U test was used to compare the parameters between the two groups. Receiver operating characteristic (ROC) curve analysis was performed to identify the best cut-off value and to evaluate whether SUVmaxLN and also SUVmaxLN/SUVmaxPT, SUVmaxLN/SUVmaxA and SUVmaxLN/SUVmaxL ratios provided diagnosis of lymph node metastasis. For the calculation of sensitivity and specificity, the screening test was used. A p value <0.05 was accepted as statistically significant.

Results

Patients general characteristics are given in Table 1. Histopathological examination revealed 71 metastatic lymph nodes in 21 patients (mean=3.5; range=1-12). On 18F-FDG PET/CT imaging, 68 lymph nodes showing increased FDG uptake were evaluated by histopathological examination and metastasis was detected (Figure 1), but the histopathological examination of 26 lymph nodes showing 18F-FDG involvement showed no metastasis. There was no pathological involvement on 18F-FDG PET/CT in 3 lymph nodes with metastasis in 1 patient.

Table 1
Figure 1

In patients with metastatic lymph nodes, the primary tumor SUVmax values were significantly higher than non-metastatic patients (26.76±10.43 vs 17.73±8.14; p=0.001). Mean SUVmaxLN, SUVmaxLN/SUVmaxL ratio, SUVmaxLN/SUVmaxA ratio, and SUVmaxLN/ SUVmaxPT ratio were significantly higher in patients with metastatic lymph nodes than non-metastatic nodes (Table 2).

Table 2

For diagnosis of lymph node metastasis with ROC analysis, the cut-off point for SUVmaxLN was 3.87 (AUC 0.856, p: 0.000) with the sensitivity of 83.7%, specificity 77%, positive predictive value (PPV) 89.1% and negative predictive value (NPV) 58% (Figure 2). The cut-off point for SUVmaxLN/SUVmaxL was 1.08 (AUC 0.833, p=0.000), with a sensitivity of 84.1%, specificity of 76%, PPV 90.6%, and NPV 63.3% (Figure 3). The cut-off point for SUVmaxLN/SUVmaxA was 1.78 (AUC 0.822, p=0.000) for the diagnosis of lymph node metastasis. The sensitivity of this value was 79.7%, specificity was 84%, PPV was 93.2%, and NPV was 60% (Figure 4). The cut-off point for SUVmaxLN/SUVmaxPT was 0.36 (AUC 0.666, p: 0.014) for the diagnosis of lymph node metastasis, with a sensitivity of 53.6%, specificity 76%, PPV 86.1%, and NPV 37.3% (Figure 5). When SUVmaxLN >2.5 was taken as a criterion for the detection of metastatic lymph nodes, the sensitivity was 95.7%, the specificity was 26.9%, PPV was 78%, and NPV was 70%.

Figure 2
Figure 3
Figure 4
Figure 5

Discussion

Quantitative data obtained using 18F-FDG PET/CT can be useful for lymph node assessment in addition to visual evaluation. In general practice, if a lymph node shows 18F-FDG uptake and SUVmax value is more than 2.5, it is more likely to be malignant (13). But, SUVmax value does not have sufficient diagnostic capability to detect metastatic lymph nodes in head and neck cancer. In our study, if SUVmax >2.5 was taken as the criterion for detection of metastatic lymph node, the sensitivity would be 95.7% and the specificity would be 26.9%. To increase diagnostic accuracy for detecting metastatic lymph nodes, different lymph node SUVmax cut-off value and proportional ratios reproduced from lymph node SUVmax are used ( 12,14,15,16,17).

In our study, the mean SUVmax values, SUVmaxLN/SUVmaxL ratio, SUVmaxLN/ SUVmaxA ratio, and SUVmaxLN/SUVmaxPT ratio of metastatic lymph nodes were significantly higher than non-metastatic lymph nodes. In the ROC analysis, the cut-off point for SUVmaxLN was 3.87 for the diagnosis of lymph node metastasis, with a sensitivity of 83.7% and specificity of 77%. A study by Marshall et al. (16) included 114 patients with head and neck cancer and found that SUVmax cut-off was 3.9 and that yielded a sensitivity of 85% and specificity of 73%. Suenaga et al. (17) used a SUVmax cut-off value of 3.65 and found that sensitivity, specificity, and accuracy of 18F-FDG PET/CT on a level by level basis were 72.9, 96.8, and 92.1%, while sensitivity, specificity, and accuracy of CT were 52.9, 98.6, and 89.6%, respectively (17).

In our study, cut-off values for SUVmaxLN/SUVmaxL and SUVmaxLN/ SUVmaxA were 1.08 and 1.78, respectively. The sensitivity and specificity for these cut-off values were 84.1%-76% and 79.7%-84%, respectively. These proportional values were proven to have higher AUC compared to SUVmaxLN/SUVmaxPT ratio and have high diagnostic power for the diagnosis of metastatic lymph node. We think that this situation is due to the variance in SUVmax of the primary tumor due to the size or histopathological features of the tumor. The specificity of all 3 proportional values we examined in our patient group was higher when SUVmax >2.5 criterion was used. Lim et al. (12) studied 74 patients with HNSCC and found that nodal SUVmax ≥3.16 yielded a sensitivity of 74.4% and specificity of 84.9% in detecting metastatic nodes and also that nodal SUVmaxLN/SUVmaxL ratio ≥0.90 yielded a sensitivity of 74.1% and specificity of 93.4%.

Study Limitations

There are some limitations of the present study. It was a retrospective study with a limited number of patients. As the study was retrospective, there were technical impediments to the matching of the lymph nodes detected on 18F-FDG PET/CT imaging and histopathological examination. Because the precise spatial correlation between 18F-FDG PET/CT and histopathology was impossible and one to one matching between them showed increased uptake on 18F-FDG PET/CT and metastatic lymph nodes on histopathologic evaluation could not be attributed due to the retrospective study design; analysis of results of the study should use this model. Therefore, there is a need for prospective studies with larger samples.

Conclusion

SUVmaxLN/SUVmaxA, SUVmaxLN/SUVmaxL, and SUVmaxLN/SUVmaxPT ratios can be used safely for diagnostic evaluation of metastasis in cervical lymph nodes on 18F-FDG PET/CT imaging in patients with LSCC.

References

1
Steuer CE, El-Deiry M, Parks JR, Higgins KA, Saba NF. An Update on Larynx cancer. CA Cancer J Clin 2017;67:31-50.
2
Kim SY, Kim JS, Doo H, Lee H, Lee JH, Cho KJ, Choi SE, Nam SY, Roh JL. Combined [18F] fluorodeoxyglucose positron emission tomography and computed tomography for detecting contralateral neck metastases in patients with head and neck squamous cell carcinoma. Oral Oncol 2011;47:376-380.
3
Ceylan Y, Ömür Ö, Hatipoğlu F. Contribution of 18F-FDG PET/CT to staging of Head and Neck Malignancies. Mol Imaging Radionucl Ther 2018;27:19-24.
4
Sun R, Tang X, Yang Y, Zhang C. 18F-FDG PET/CT for the detection of regional nodal metastasis in patients with head and neck cancer: a meta-analysis. Oral Oncol 2015;51:314-320.
5
Adams MC, Turkington TG, Wilson JM, Wong TZ. A systematic review of the factors affecting accuracy of SUV measurements. Am J Roentgenol 2010;195:310-320.
6
Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med 2009;50(Suppl 1):11-20.
7
Weiss GJ, Korn LR. Interpretation of PET Scans: Do Not Take SUVs at Face Value. J Thoracic Oncol 2012;7:1744-1746.
8
Mattes MD, Moshcinsky AB, Ahsanuddin S, Rizk NP, Foster A, Wu AJ, Ashamalla H, Weber WA, Rimner A. Ratio of Lymph Node to Primary Tumor SUV on PET/CT Accurately Predicts Nodal Malignancy in Non-Small Cell Lung Cancer. Clin Lung Cancer 2015;16:253-258.
9
Lee AY, Choi SC, Jung KP, Park JS, Lee SM, Bae SK. Characteristics of Metastatic Mediastinal Lymph Nodes of Non-Small Cell Lung Cancer on Preoperative F-18 FDG PET/CT. Nucl Med Mol Imaging 2014;48:41-46.
10
Sun YW, Choi YC, Song Y. Prediction of Axillary Nodal Status according to the Axillary Lymph Node to Primary Breast Tumor Maximum Standardized Uptake Value Ratio on 18F-fluorodeoxyglucose Positron Emission Tomography/ Computed Tomography. J Breast Dis 2016;4:92-99.
11
Gedik GC, Kara PO, Kara T, Sari O, Kara F. Evaluation of FDG uptake in pulmonary hila with FDG PET/CT and contrast-enhanced CT in patients with thoracic and non-thoracic tumors. Ann Nucl Med 2010;24:593-599.
12
Lim RSM, Ramdave S, Beech S, Billah B, Karim MN, Smith JA, Safdar A, Sigston E. Utility of SUVmax on 18F-FDG PET in detecting cervical nodal metastases. Cancer Imaging 2016;16:39-47.
13
Plaxton NA, Brandon DC, Corey AS, Harrison CE, Karagulle Kendi AT, Halkar RK, Barron BJ. Characteristics and Limitations of 18F-FDG PET/CT for Imaging of Squamous Cell Carcinoma of the Head and Neck: A Comprehensive Review of Anatomy, Metastatic Pathways, and Image Findings. AJR Am J Roentgenol 2015;205:519-531.
14
Matsubara R, Kawano S, Chikui T, Kiyosue T, Goto Y, Hirano M, Jinno T, Nagata T, Oobu K, Abe K, Nakamura S. Clinical significance of combined assessment of the maximum standardized uptake value of 18F-FDG PET with nodal size in the diagnosis of cervical lymph node metastasis of oral squamous cell carcinoma. Acad Radiol 2012;19:708-717.
15
Murakami R, Uozumi H, Hirai T, Nishimura R, Shiraishi S, Ota K, Murakami D, Tomiguchi S, Oya N, Katsuragawa S, Yamashita Y. Impact of 18F-FDG PET/CT imaging on nodal staging for head-and-neck squamous cell carcinoma. Int J Radiat Oncol Biol Phys 2007;68:377-382.
16
Marshall RA, Som PD, Uliel L, Buckstein M, Gupta V, Miles B, Gandikota N, Corcuera-Solano I, Misiukiewicz K, Sikora AG, Kostakoglu L. Combined Evaluation of 18F-FDG PET/CT and CT Imaging Characteristics of Cervical Lymph Nodes to Increase the Interpretation Accuracy for Nodal Metastatic Involvement in Head and Neck Cancer. Otolaryngol (Sunnyvale) 2015;5:213.
17
Suenaga Y, Kitajima K, Kanda T, Otsuki N, Nibu K, Sasaki R, Itoh T, Sugimura K. 18F-FDG PET/CT imaging for detection of nodal metastases in patients with squamous cell carcinoma of the pharynx and larynx: comparison with CT. Jpn J Radiol 2016;34:203-210.